Glazing, CO₂ and U-value

The Insights bar at the bottom of the controller shows three numbers for the current design. They update every time the facade changes, so you can see the effect of a decision as you make it.

Insights bar showing glazing 38 %, CO₂ 88 kg/m² and U-value 0.59 W/m²K

All three are early-design estimates. They help you compare options and steer a design; they don’t replace an energy calculation, a life-cycle assessment or a compliance check.

Facade area

All three numbers relate to the facade area: the area of your linked surfaces. CO₂ is given per m² of facade area, and glazing as a share of it.

Glazing

The share of the facade area that is transparent glass.

  • Counts elements whose material is transparent glazing.
  • Opaque glazed panels (spandrel panels, insulated metal panels) don’t count as glazing.
  • An outer second-skin glass doesn’t count either — it sits in front of the facade, not in it.

Hover for the glass area, the facade area and the ratio.

CO₂

The embodied carbon of everything on the facade, in kg CO₂e per m² of facade area.

  • Every element with a material from the library counts: walls, glazing, profiles, claddings, screens.
  • Walls and claddings count at their nominal build-up; only materials in their Massive variant count by volume. See Assemblies and facade thickness.
  • The life-cycle stages included are set in Facet Settings → Performance Targets → CO2 scope. The default is A1–A3 + C3 + C4 (production plus end of life), which treats timber and other bio-based materials fairly. With A1–A3 alone, they read negative, because the carbon they store is only released at end of life.

Hover for a breakdown by element, largest first, with each element’s share.

Insights bar showing glazing 60 %, CO₂ 260 kg/m² and U-value 0.86 W/m²K, with the CO₂ breakdown by element shown on hover

U-value

The facade’s average heat loss in W/m²K: lower is better insulated.

  • An area-weighted average of the elements that have a U-value: walls (assemblies) and glazing.
  • Elements without a thermal role — fins, screens, profiles — don’t count.
  • A second-skin glass in front of glazing improves the glazing’s U-value for the part it covers.
  • Based on typical build-ups and EN ISO 6946; frames, junctions and thermal bridges are only roughly included.

Hover to see the share of the facade the average covers (Coverage of Facade Area), each element’s U-value, and the weighted mean.

Coloured dots: your targets

Each number has a dot: green on target, yellow close, red off target. Set the limits in Facet Settings → Performance Targets:

MetricDefault greenDefault red
CO₂ (kg/m²)below 100above 200
U-Value (W/m²K)below 1.0above 1.6
Glazing (%)0–40 %outside 0–60 %

Glazing is a range: a facade can have too little glass as well as too much. Targets are stored with the material library, so an exported library shares your office’s goals.

In the viewport

The data card button next to the insights shows the three numbers as a small card in the viewport’s corner.

Insights bar with the data card button highlighted in the top-right corner

It stays in view captures (ViewCaptureToClipboard), so it’s handy for quick comparisons in presentations.

Data card in the corner of the Rhino viewport showing glazing 38 %, CO₂ 88 kg/m² and U-value 0.59 W/m²K for an Interlocked Screen facade

Not clear? More questions? Reach out to thomas@facet3d.com